Rich Electric

EI-9001 AC Drive

220V Class (3-Phase Input) 0.75kW~75kW
440V Class (3-Phase Input) 0.75kW~900kW

AC Inverter Motor Drive is the comprehensive flux vector control AC inverter. AC Inverter Motor Drive can be used in elevator, lift application. There are four control patterns: Standard V/F control, V/F control with PG feedback, Sensorless flux vector control and vector control with PG feedback. EI-Super provides the servo-like precision machinery to multiple types of motor drives. The capacity of AC Inverter Motor Drive is up to 900kW. Large power can be custom-designed in the cabinet protection.

AC Inverter Motor Drive is a general-purpose inverter with flux vector control. It directly controls the current or torque in an AC induction motor. AC Inverter Motor Drive is suitable for a wide variety of applications.
AC Inverter Motor Drive provides smooth start-up at low speeds (1% of rated speed) and precise operation. Its auto-tuning function enables high performance tuning of all induction motors

  • open loop vector
  • flux vector
  • V/F control with PG feedback
  • V/F control



32bit DSP microprocessor configuration

  • magnetic field oriented flux vector contro
  • auto-tune ability
  • available for speed-type servo controller while PG feedback added
  • RS-232/RS-485 serial communication port
  • RS232/TCP-IP interface card
  • capacities from 1HP – 400 HP
  • optional DC reactor available (for reducing harmonic interference from the power supply)
  • multi-language large screen LCD displays the drive status in six languages and a parameter copy mode function.
  1. English
  2. Chinese
  3. Russian
  4. German
  5. French
  6. Spanish

EI-Super N features full-scale flux vector current control that directly controls motor torque based on present control theory utilising a magnetic flux observer and neuro-control.

It features full torque control even at zero speed when PG option is added.

EI-Super N features highly precise operation throughout the motor’s entire speed range, even under fluctuating load conditions.

Four control methods are included:
  • Standard V/F control
  • V/F control with PG feedback
  • Sensorless flux vector control
  • Flux vector current control with PG feedback

Simply select the parameters, EI-Super N can be applied to a wide range of applications from servo-like precision machinery to multiple motor drives.

Factory presets default to sensorless vector control type, but it can be configured to the V/F control mode for applications requiring multiple motors on one device, or set to flux vector current control mode (with PG) for hughly precise vector operation. (PG-B interface card is optional)

Note: at low speed, high torque and continuous operation, a forced cooling special motor must be used
  • Booster Oil Pumping Station
  • Punch Press
  • Tram Line in Mining Operation
  • Surface Winder
  • Application requirements; V/Hz (2%), sensorless vector (0.1%), or flux vector control (0.01% with motor-mounted encoder and drive-mounted PG-X2 card required)